Property X-FOAM® HBT 300

back to X-FOAM® HBT 300
SVOJSTVO EN METODA JEDINICA MJERE VRIJEDNOSTI
DEBLJINE EN 823 mm 30 - 300
TOLERANCIJA DEBLJINE (T1)      
Debljina < 50 mm EN 823 mm -2 / +2
Debljine od 50 mm do 120 mm EN 823 mm -2 / +3
Debljine > 120 mm  EN 823 mm -2 / +6
Duljina EN822 mm 1250
Ŝirina EN822 mm 600
Tolerancija duljine (I) i širine (b) EN13164 mm I ili b ≤ 1500: +/- 8
I ili b ≤ 1500: +/- 10
Tolerancija na pravokutnost (Sb) EN824 / EN13164 mm/m 5
Tolerancija ravnosti (Smax) EN825 / EN13164 mm/m 6
Gustoća   kg/m3 33 +/- 10%
Specifični toplinski kapacitet   J/kgK 1450

 

SVOJSTVO EN METODA JEDINICA MJERE VRIJEDNOSTI
DEKLARIRANA TOPLINSKA VODLJIVOST (λD) I DEKLARIRANI TOPLINSKI OTPOT (RD)     λD RD
Debljina 30mm  EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,032 0,90
Debljina 40mm EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,033 1,20
Debljina 50mm  EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,034 1,45
Debljina 60mm EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,034 1,75
Debljina 80mm EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,035 2,25
Debljina 100mm EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,035 2,85
Debljina 120mm EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,036 3,30
Debljina 140mm EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,034 4,15
Debljina 160mm EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,034 4,70
Debljina 180mm EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,034 5,25
Debljina 200mm EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,035 5,75
Debljina 220mm EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,035 6,30
Debljina 240mm EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,035 6,85
Debljina 260mm EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,035 7,45
Debljina 280mm EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,035 8,00
Debljina 300mm EN 13164 / EN12667 λDW/mK - RD: m2K / W 0,035 8,55
TLAČNA ČVRSOĆA PRI 10% DEFORMACIJI USLIJED OPTEREĆENJA ILI LOMA EN 826 kPa 300
TLAČNA ČVRSOĆA NAKON 50 GODINA POD OPTEREĆENJEM ≤ 2% EN 1606 kPa 120
DIMENZIJSKA STABILNOST PRI 70 °C I 90% RELATIVNE VLAŽNOSTI
PROMJENE U DEBLJINI, DUŽINI I ŠIRINI
EN 1604 % < 5
PONAŠANJE NA DEFORMACIJE.
UVJETI ISPITIVANJA 70 °C, 168 sati, 40 kPa
EN 1605 % < 5
APSORPCIJA VODE URANJANJEM
(28 DANA)
EN 12087 Vol % ≤ 0,7
APSORPCIJA VODE DIFUZIJOM (28 DANA)      
Debljine od 30 mm do 50 mm EN 12088 Vol % ≤ 5
Debljine od 60 mm do 300mm EN 12088 Vol % ≤ 3
OTPORNOST NA DIFUZIJU VODENE PARE (μ)      
Debljina 30 mm EN 12086   150
Debljine od 40 mm do 300 mm EN 12086   100
PONAŠANJE KOD SMRZAVANJA NAKON APSORPCIJE VODE DUGOTRAJNOM DIFUZIJOM      
Debljine od 30 mm do 50mm EN 12091 Vol % FTCD1                    ≤ 2
Debljine od 60 mm do 300mm EN 12091 Vol % FTCD1                    ≤ 1
REAKCIJA NA POŽAR EN 13501-1 Razred E
GRANIČNA TEMPERATURA UPORABE   °C + 75
PROSJEK ZATVORENIH STANICA   % > 96